Information Bus: Testing and Inspection
CCD BUS FAILUREThe CCD data bus can be monitored using the DRB III. However, it is possible for the data bus to pass all tests since the voltage parameters will be in range" and false signals are being sent. There are essentially 12 "hard failures" that can occur with the CCD data bus:
- Bus Shorted to Battery
- Bus Shorted to 5 Volts Bus Shorted to Ground
- Bus (+) Shorted to Bus (-)
- Bus (-) and Bus (+) Open
- Bus (+) Open Bus (-) Open
- No Bus Bias
- Bus Bias Level Too High
- Bus Bias Level Too Low
- No Bus Termination
- Not Receiving Bus Messages Correctly
BUS FAILURE VISUAL SYMPTOM DIAGNOSIS
The following visible symptoms or customer complaints, alone or in combination, may indicate a CCD data bus failure:
- Airbag Indicator Lamp and Malfunction Indicator Lamp (MIL) Illuminated
- Instrument Cluster Gauges (All) Inoperative
- No Remote Keyless Entry (RKE) Operation
- No Compass Mini Trip Computer (CMTC) Operation