Operation CHARM: Car repair manuals for everyone.

Driver Squib 1 Circuit Open (Active)

Test 1:




Tests 2 - 3:




Tests 4 - 5:





SYMPTOM
DRIVER SQUIB 1 CIRCUIT OPEN - ACTIVE

WHEN MONITORED
When the ignition is ON, the ACM monitors the resistance of the Driver Squib 1 circuits.

SET CONDITION
The ACM has detected an open circuit or high resistance in the Driver Squib 1 circuits.

POSSIBLE CAUSES
- Driver airbag open
- Clockspring, driver airbag circuits open
- Driver airbag line 2 open
- Driver airbag line 1 open
- ACM, driver airbag circuit open