Driver Squib 1 Circuit Open (Active)
Test 1:
Tests 2 - 3:
Tests 4 - 5:
SYMPTOM
DRIVER SQUIB 1 CIRCUIT OPEN - ACTIVE
WHEN MONITORED
When the ignition is ON, the ACM monitors the resistance of the Driver Squib 1 circuits.
SET CONDITION
The ACM has detected an open circuit or high resistance in the Driver Squib 1 circuits.
POSSIBLE CAUSES
- Driver airbag open
- Clockspring, driver airbag circuits open
- Driver airbag line 2 open
- Driver airbag line 1 open
- ACM, driver airbag circuit open