Passenger Squib 1 Shorted to Ground (Active)
Test 1:
Tests 2 - 4:
SYMPTOM
PASSENGER SQUIB 1 SHORT TO GROUND - ACTIVE
WHEN MONITORED
Continuously with the ignition ON.
SET CONDITION
The ACM has detected a short to ground in the Passenger Squib 1 circuits.
POSSIBLE CAUSES
- Passenger airbag circuits short to ground
- Passenger airbag line 1 short to ground
- Passenger airbag line 2 short to ground
- ACM, passenger airbag circuit short to ground