Manual
REMOVAL1. Remove the waterdam.
Door Glass/Regulator:
2. Raise the glass to the position shown and using a long flat blade or hook type tool, disengage clips attaching glass retainer to regulator lift plate.
3. Disconnect the glass from the regulator lift plate and re-install the clips.
4. Secure the glass in the up position using a wood wedge, tape or equivalent.
Front Door Regulator - Manual:
5. Loosen the bolts.
6. Disconnect the runout tube clip and remove the regulator
INSTALLATION
1. Install the regulator assembly.
Regulator Tightening Sequence - Manual:
2. Tighten the bolts to 9 N.m (80 in.lbs.) using the sequence shown.
3. Remove the glass support and connect to the regulator lift plate.
4. Install the waterdam.