Left Curtain Squib 1 Circuit Shorted
Test 1:
Test 2 - 3:
Test 4:
SYMPTOM
LEFT CURTAIN SQUIB 1 CIRCUIT SHORT
WHEN MONITORED
With the ignition on, the ACM monitors the resistance between the Left Curtain Squib 1 circuits.
SET CONDITION
When the ACM detects a low resistance between the Left Curtain Squib 1 circuits.
POSSIBLE CAUSES
- Left curtain squib 1 circuit short
- Left curtain squib 1 line 1 short to line 2
- ACM, Left curtain squib 1 circuit short
- Stored code or intermittent condition
- Active code present