Operation CHARM: Car repair manuals for everyone.

Installation






INSTALLATION

NOTE: Illustrations shown with instrument panel removed for clarity.





NOTE: LHD model shown. RHD model similar.

1. Position the recirculation door actuator (1) to the right side of the HVAC air inlet housing (2).

2. Install the recirculation door actuator onto the air inlet housing. If necessary, rotate the actuator slightly to align the splines on the actuator output shaft (3) with those on the recirculation door pivot shaft adapter (4).




3. Install the screws (1) that secure the recirculation door actuator (2) to the air inlet housing (3). Tighten the screws to 2 Nm (17 in. lbs.).

4. Connect the instrument panel wire harness connector (4) to the recirculation door actuator.

5. Install the glove box bin.

6. Reconnect the negative battery cable.