Air Cleaner Housing - Installation
INSTALLATION
1. Position the lower housing and attach the air inlet duct.
2. Install the lower housing to fender well fastener. Tighten fastener to 5 Nm (44 in. lbs.).
3. Install the air cleaner element.
4. Position housing cover (2) into housing locating tabs.
5. Pry up spring clips (1) and lock cover (2) to housing.
6. Install the air outlet tube. tighten clamp to 5 Nm (44 in. lbs.).
7. Connect the MAF (4) and air pressure sensor (3) wire harness connectors.
8. Connect the negative battery cable.
Intake Air Tube
1. Before tightening any clamps or fasteners perform the following.
NOTE: Incorrect installation or miss alignment of the air tube can result oil leaks.
2. Slide Air Inlet tube flex hose over airbox outlet fitting.
3. Slide air Inlet tube over Turbo inlet fitting ensure that Orange seal is not rolled and is proper positioned.
4. Install retaining fastener located approximately 1 - 2 inches down stream of the airbox flex hose and tighten to specified torque. This will hold the tube in the proper position so that the clamps can now be tightened.
5. Tighten clamp on the Turbo inlet end first to the proper specified torque. Over torque of the clamp may result in breakage of the air tube
6. Tighten clamp on the Airbox outlet flex hose end to the proper specified torque. Over torque of the clamp may result in breakage of the air tube
7. Attach CCV hose at Oil separator. (During removal of the CCV hose do NOT disconnect CCV hose at the Air Tube)