B1851
B1851-FLIPPER GLASS SWITCH STUCK
For a complete wiring diagram, refer to the Wiring Information.
- When Monitored:
Continuously
- Set Condition:
When the Cluster senses a low condition on the Flip-UP (Flipper) Glass Switch Sense circuit for over 10 seconds, this code will set.
1. TEST FOR INTERMITTENT CONDITION
1. With the scan tool, record and erase DTCs
2. Operate the Flip-Up Glass Switch several times.
3. Cycle the ignition from on to off 3 times.
4. Turn the ignition on.
5. With the scan tool, read DTC's.
Does the scan tool display B1851-FLIPPER GLASS SWITCH STUCK?
Yes
- Go To 2
No
- The conditions that caused this code to set are not present at this time. Using the wiring diagram/schematic as a guide, inspect the wiring and connectors.
- Perform the BODY VERIFICATION TEST Body Verification Test.
2. FLIP-UP GLASS SWITCH STUCK
1. With the scan tool, erase DTCs.
2. Disconnect the License Lamp connector.
3. With the scan tool, read DTCs.
Does the scan tool display FLIPPER GLASS SWITCH STUCK?
No
- Replace the Flip-Up Glass Switch (License Lamp).
- Perform the BODY VERIFICATION TEST Body Verification Test.
Yes
- Go To 3
3. (Q80) FLIP-UP GLASS SWITCH SENSE CIRCUIT SHORT TO GROUND
1. Turn the ignition off.
2. Disconnect the Cluster C1 connector.
3. Measure the resistance between ground and the (Q80) Flip-Up Glass Switch Sense circuit.
Is the resistance below 1000.0 ohms?
Yes
- Repair the (Q80) Flip-Up Glass Switch Sense circuit for a short to ground.
- Perform the BODY VERIFICATION TEST Body Verification Test.
No
- Replace the Instrument Cluster.
- Perform the BODY VERIFICATION TEST Body Verification Test.