Front Air Inlet Housing
HOUSING-AIR INLET
NOTE: The air inlet housing must be removed from HVAC housing and disassembled for service of the recirculation-air door.
NOTE: LHD model shown. RHD model similar.
1. Position the air distribution housing (4) onto the top of the HVAC housing (5) by inserting the two tabs located at the front of the air inlet housing into the slots located on the top of the HVAC housing.
2. Tip the air distribution housing downward until it is properly seated on the HVAC housing.
3. Install the three screws (3) that secure the air distribution housing to the HVAC housing. Tighten the screws to 2.2 Nm (20 in. lbs.).
4. Connect the HVAC wire harness (1) to the recirculation door actuator (2).
5. Install the HVAC housing assembly HVAC Housing - Installation.