Blend Door Actuator - Installation
INSTALLATION
NOTE: LHD model shown. RHD model similar.
1. Position the blend door actuator (2) onto the left side of the HVAC air distribution housing (3). If necessary, rotate the actuator slightly to align the splines on the actuator output shaft with those in the blend air door linkage.
2. Install the two screws (4) that secure the blend door actuator to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
3. Connect the wire harness connector (1) to the blend door actuator.
4. On RHD models, install the glove box bin Instrument Panel Glove Box - Installation.
5. On RHD models, install the silencer panel and two push-pins.
6. Reconnect the negative battery cable.
7. Initiate the Actuator Calibration function using a scan tool .