Operation CHARM: Car repair manuals for everyone.

Blower/Evaporator-Rear

Removal
1. Discharge refrigerant from A/C system. Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper procedures.
2. Disconnect inlet and outlet pipe from evaporator.

NOTE: Immediately plug all open fittings to keep moisture out of system.

3. Disconnect wiring harness connector.
4. Remove blower/evaporator unit.

Installation
1. Install blower/evaporator unit in reverse order of removal.
2. Evacuate refrigerant system. Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper procedures.
3. Charge A/C system. Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper procedures.

NOTE:
a. Immediately plug all open fittings to keep moisture out of system.
b. Apply clean compressor oil to O-rings before connecting fittings.
c. Do not apply compressor oil to fillings.
d. When installing new evaporator; add compressor oil.

Compressor oil : 2.44 cu in (40 cc)

Tightening torque : 87 - 140 lb.in (10 - 16 N.m, 100 - 160 Kg.cm)