Blower Unit
REPLACEMENT1. Disconnect the negative (-) battery terminal.
2. Remove the crash pad. Dashboard / Instrument Panel
3. Disconnect the connectors from the intake actuator, the blower motor and power MOSFET.
4. Remove the cowl cross bar assembly.
5. Remove the blower unit (A) from the heater unit after loosening a mounting bolt and 2 screws.
NOTE: Make sure that there is no air leaking out of the blower and duct joints.
6. Installation is the reverse order of removal.