Battery Test Procedure
THE MICRO 570 ANALYZERThe MICRO 570 Analyzer provides the ability to test the charging and starting systems, including the battery, starter and generator.
CAUTION: Because of the possibility of personal injury, always use extreme caution and appropriate eye protection when working with batteries.
KEY PAD
The MICRO 570 button on the key pad provides the following functions.
BATTERY TEST PROCEDURE
1. Connect the tester to the battery.
- Red clamp to battery positive (+) terminal.
- Black clamp to battery negative (-) terminal.
CAUTION: Connect clamps securely. If "CHECK CONNECTION" message is displayed on the screen, reconnect clamps securely.
2. The tester will ask if the battery is connected "IN A VEHICLE" or "OUT OF A VEHICLE". Make your selection by pressing the arrow buttons; then press ENTER.
3. Choose either CCA or CCP and press the ENTER button.
NOTE:
- CCA : Cold cranking amps, is an SAE specification for cranking batteries at -18 degrees C (0 degrees F).
- CCP : Cold cranking amps, is an SAE specification for korean manufacturer's for cranking batteries at -18 degrees C (0 degrees F).
4. Set the CCA value displayed on the screen to the CCA value marked on the battery label by pressing up and down buttons and press ENTER.
NOTE: The battery ratings (CCA) displayed on the tester must be identical to the ratings marked on battery label.
5. The tester (Micro 570) displays battery test results including voltage and battery ratings
A relevant action must be given according to the test results by referring to the battery test results as shown in the table.
NOTE: The battery ratings (CCA) displayed on the tester must be identical to the ratings marked on battery label.
6. To conduct starter test, press ENTER.
Battery Test Results:
BATTERY TEST RESULTS
WARNING: Whenever filing a claim for battery, the print out of the battery test results must be attached.