Operation CHARM: Car repair manuals for everyone.

Purge Control Solenoid Valve (PCSV)

PURGE CONTROL SOLENOID VALVE (PCSV)

INSPECTION




FUNCTION AND OPERATION PRINCIPLE
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.

Specification:




SPECIFICATION

Schematic Diagram:




SCHEMATIC DIAGRAM

COMPONENT INSPECTION
1. Turn ignition switch OFF.
2. Disconnect PCSV connector.
3. Measure resistance between PCSV terminals 1 and 2.
4. Check that the resistance is within the specification.

Specification: Refer to SPECIFICATION.