Inspection/Repair - W/Harness Inspection
Terminal and Connector Inspection
1. Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found?
Right Turn Signal Lamp Circuit Inspection
Check short to ground in harness
1. IG "OFF" or IG "ON" & ENG "OFF"
2. Disconnect FAM connector.
3. Measure resistance between the right turn signal lamp terminal of FAM harness connector and ground of the right turn signal lamp.
Specification : Approx. 1 Ohm
4. Is the measured resistance within specification?