Repair Procedures
Replacement
1. Discharge refrigerant from refrigeration system.
2. Replace faulty tube or hose.
CAUTION:
- Cap the open fittings immediately to keep moisture or dirt out of the system.
3. Tighten joint of bolt or nut to specified torque
CAUTION:
- Connections should not be torque tighter than the specified torque.
4. Evacuate air in refrigeration system and charge system with refrigerant.
Specified amount :
Front only : 600 ± 25 (lambda3.8) , 750 ± 2.5 (T 4.6)
Front & rear : 750 ± 25 (lambda3.8) , 950 ± 2.5 (T 4.6)
5. Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant.
6. Inspect A/C operation.