Inspection/Repair - W/Harness Inspection
Terminal and Connector Inspection
1. Many malfunctions in the electrical system are caused by poor harness(es) and terminal condition. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found?
Power Circuit Inspection
Open or Short Check
1. Ignition "ON" & Engine "OFF".
2. Measure voltage between power terminal of the G sensor harness connector and chassis ground.
Specification : Approx. 5V
3. Is the measured value within specifications?
Ground Circuit Inspection
Open or Short Check
1. Ignition "OFF" & Engine "OFF".
2. Disconnect the G sensor connector.
3. Measure resistance between ground terminal of the G sensor harness connector and chassis ground.
Specification : Approx. below 1 Ohm
4. Is the measured value within specifications?
Signal Circuit Inspection
Open or Short Check
1. Ignition "ON" & Engine "OFF".
2. Disconnect the G sensor connector and HECU connector.
3. Measure resistance between signal terminal of the G sensor harness connector and G sensor signal terminal of the HECU harness connector.
Specification : Approx. below 1 Ohm
4. Is the measured value within specifications?