General Information
Component Location
General Description
Shift motor is used to change working range of transfer by utilizing Auto/low selection switch.
AUTO -> LOW Mode : 05, 12 terminal B (+), 04, 11 terminal (Ground)
LOW -> AUTO Mode : 04, 11 terminal B (+), 05, 12 terminal (Ground)
DTC Description
This trouble code is set when motor has open circuit or is shorted to battery.
DTC Detecting Condition
Schematic Diagram
Signal Waveform