A/C - Uncomfortable Air Distribution
No: 80/01/03/NASRef:
Issue: 1
Date: 02/07/03
Footwell Air Distribution Improvement
AFFECTED VEHICLE RANGE:
Freelander (LN) 3A222742 to 3A226777
SITUATION:
DIRECT VENTILATION PATH CAUSES DISCOMFORT
The ventilation system ducting on Freelander vehicles directs high volume air flow onto the drivers right foot at certain distribution settings that can become uncomfortably hot or cold.
RESOLUTION:
INSTALL DEFLECTOR TO DISTRIBUTE AIR FLOW
Upon customer complaint of excessive heat to the foot well, perform the corrective steps in this bulletin to ensure a more even distribution of HVAC system air.
PARTS INFORMATION:
JEP500050 HVAC diverter duct Qty 1
WARRANTY CLAIMS:
80.20.89/33 Time 0.10 hrs.
Install deflector on ventilation ducting
Normal warranty policy and procedures apply.
Material allowance is included in labor operation.
REPAIR PROCEDURE
MODIFY AIR FLOW TO FOOTWELL
1. Locate the heater lower vent, situated on the driver's side adjacent to the diagnostic socket.
2. Cut and remove the heater flap situated inside the heater lower vent. (Arrowed in Figure 1).
3. Position the heater duct diverter, to the heater lower vent (A in Figure 2).
4. Insert the provided screw through the diverter and secure the diverter to cover the lower heater duct vent. (B in Figure 2)