Battery - Disconnect Unit (SRS)



Battery - Disconnect Unit (SRS)

Service Repair No - 76.74.14


Before disconnecting the battery, ensure all text and cautions in the battery disconnection section are observed.

WARNING:
^ It is imperative that before any work is undertaken on the SRS system, the appropriate information is read thoroughly.
^ Always disconnect both battery leads before beginning work on the SRS system. Disconnect the negative lead first. Never reverse connect the battery.


Remove
1. Make the SRS system safe.





2. Release cover and remove nut securing positive lead to the battery disconnect unit. Position the positive lead aside.
3. Release cover and loosen nut securing battery disconnect unit to the battery terminal.
4. Disconnect multiplug from the battery disconnect unit.
5. Remove cover and nut securing battery disconnect unit to the junction box.
6. Remove the battery disconnect unit.

Refit

NOTE: If the SRS component is to be replaced, the bar code of the new unit must be recorded.

1. Ensure battery terminals are clean.
2. Position battery disconnect unit to junction box, fit nut and tighten to 25 Nm (18 lbf.ft). Fit cover.
3. Fit battery disconnect unit to the positive battery terminal and tighten nut. Fit cover.
4. Position positive lead to the battery disconnect unit, fit nut and tighten to 25 Nm (18 lbf.ft). Fit cover.
5. Connect multiplug to battery disconnect unit.
6. Connect battery leads, earth lead last.