Blower Motor: Service and Repair
Blower Motor - LHD
Special Service Tools
Remover/Installer, Blower Motor
Removal
NOTE: The recirculation blend door must be closed in order for the removal of the recirculation blend door housing.
1. Activate recirculation.
2. Disconnect the battery ground cable.
3. Remove the accelerator pedal assembly.
4.
5. Remove the glove compartment.
11. Remove the CJB bracket.
14. Install the special tool guide to the blower motor.
15. With the marking upwards, use the guide to install the remainder of the special tool to the blower motor.
CAUTION: Make sure that the special tool is correctly located.
Rotate the special tool counter-clockwise to release the blower motor assembly.
16. Remove the blower motor assembly.
Installation
1. Using the special tool, install the blower motor assembly approximately 10 degrees counter-clockwise from the vertical position.
2. Rotate the special tool clockwise to secure the blower motor assembly.
3. Install the recirculation blend door housing assembly.
4. Connect the recirculation blend door actuator electrical connector. Connect the air quality sensor electrical connector. Secure the wiring harness.
5. Install the CJB bracket.
Torque: 10 Nm
6. Secure the wiring harnesses to the CJB bracket.
7. Install the CJB.
8. Connect the 5 electrical connectors to the CJB and secure the front carpet.
9. Install the CJB lower access cover.
10. Install the passenger side footwell duct.
11. Install the glove compartment.
12. Connect the blower motor electrical connector.
13. Install the accelerator pedal assembly.
14. Connect the battery ground cable.