Operation CHARM: Car repair manuals for everyone.

General Specifications


General Specifications

Cooling System Type
Pressurised, thermostatically controlled with remote header tank

Radiator Cross flow with integral transmission fluid cooler
Expansion tank Remote - fitted with a bleed screw and low coolant level sensor

Pressure cap rating 110 kPa (1.1 bar / 16 psi)

Thermostat:
Starts to open 88°C (190°F)
Fully open 95°C (203°F)

Cooling fan Engine driven, viscous coupled with electronic control
Cooling fan diameter 500 mm (19.6 in)
Direction of rotation Clockwise when viewed from front of engine
Coolant pump Centrifugal flow impellor, belt driven from crankshaft