Air Conditioning





Air Conditioning

COMPONENT LOCATION









OVERVIEW
The A/C system transfers heat from the cabin to the outside atmosphere to provide the heater assembly with dehumidified cool air.
The A/C system is a sealed closed loop system, filled with a charge weight of R134a refrigerant as the heat transfer medium. The refrigerant charge weight for both i6 and TD4 vehicles is 730 g. Oil is added to the refrigerant to lubricate the internal components of the A/C compressor.
Although different units, the A/C compressors fitted to both the i6 petrol engine and the TD4 diesel engine are both variable displacement units. The displacement (flow of refrigerant) is controlled to match the thermal load of the evaporator.
Operation of the A/C system is controlled by the Automatic Temperature Control (ATC) module. For additional information, refer to Control Components Control Components

A/C COMPRESSOR

NOTE:
i6 A/C compressor shown, TD4 similar





The A/C compressor is driven by the engine accessory drive belt and circulates refrigerant around the system by compressing low pressure, low temperature vapor from the evaporator and discharging the resultant high pressure, high temperature vapor to the condenser.
To protect the system from excessive pressure, a pressure relief valve is installed in the outlet side of the A/C compressor. The pressure relief valve vents excess pressure into the engine compartment.

i6
i6 vehicles are fitted with a Zexel-Valeo KC-88 variable displacement A/C compressor. Compressor displacement is controlled by the Engine Control Module (ECM) based on current evaporator temperature and target evaporator temperature signals received from the ATC module. From these values the ECM calculates the required compressor displacement and provides a Pulse Width Modulated (PWM) signal to the compressor solenoid valve. The compressor solenoid valve is mounted on the rear of the compressor and interprets the PWM signal as a displacement value and alters the position of the internal swash plate accordingly. For additional information, refer to Control Components Control Components
The ECM will also reduce the displacement of the A/C compressor to its minimum level if 'full throttle' or automatic transmission 'kick down' is requested. This feature is not present on Gulf specification vehicles.
Compressor clutch engagement is controlled by the ECM. For additional information, refer to Control Components Control Components

TD4
TD4 vehicles are fitted with a Visteon VS16 variable displacement A/C compressor. Displacement is controlled internally by a control valve, which is integral with the compressor. The control valve measures the input and output pressures of the refrigerant entering and leaving the compressor and controls the angle of the internal swash plate accordingly.

NOTE:
There is no external control over A/C compressor swash plate angle. Consequently, compressor displacement is neither measured nor calculated by any external control component.
Compressor clutch engagement is controlled by the ECM. For additional information, refer to Control Components Control Components

CONDENSER









The condenser transfers heat from the refrigerant to the surrounding air to convert the high pressure vapor from the compressor into a liquid. The condenser is installed immediately in front of the radiator. Two brackets on each end tank attach the condenser to the end tanks of the radiator.
The condenser is classified as a sub-cooling condenser and consists of a fin and tube heat exchanger core installed between 2 end tanks. Divisions in the end tanks separate the heat exchanger into a 4 pass upper (condenser) section and a 2 pass lower (sub-cooler) section.
The RH end tank provides the connections to the high pressure line from the A/C compressor and the low pressure line to the evaporator.

RECEIVER/DRIER
The receiver/drier is integral with the condenser LH end tank and removes solid impurities and moisture from the refrigerant. It also acts as a reservoir for liquid refrigerant to accommodate changes of heat load at the evaporator.
Refrigerant entering the receiver drier passes through a filter and a desiccant pack, then collects in the base of the unit before flowing through the outlet pipe back to the condenser.

REFRIGERANT PRESSURE SENSOR





The refrigerant pressure sensor provides the ATC module with a pressure input from the high pressure side of the refrigerant system. The refrigerant pressure sensor is hardwired to the ECM, which uses the signal to control operation of the A/C compressor and to calculate the additional load on the engine when the A/C compressor is operating. The ECM also broadcasts the refrigerant high pressure value over the high speed Controller Area Network (CAN) bus to the Central Junction Box (CJB). The CJB relays the signal to the ATC module over the medium speed CAN bus to increase the amount of recirculated air if required.
The refrigerant pressure sensor is located in the refrigerant line between the condenser and the thermostatic expansion valve. For additional information, refer to Control Components Control Components

THERMOSTATIC EXPANSION VALVE









The thermostatic expansion valve meters the flow of refrigerant into the evaporator, to match the refrigerant flow with the heat load of the air passing through the evaporator.
The thermostatic expansion valve is a block type valve located behind the heater assembly, and attached to the inlet and outlet ports of the evaporator. The thermostatic expansion valve consists of an aluminum housing containing inlet and outlet passages. A ball and spring metering valve is installed in the inlet passage and a temperature sensor is installed in the outlet passage. The temperature sensor consists of a temperature sensitive tube connected to a diaphragm. The bottom end of the temperature sensitive tube acts on the ball of the metering valve. Pressure on top of the diaphragm is controlled by the evaporator outlet temperature conducted through the temperature sensitive tube. The bottom of the diaphragm senses evaporator outlet pressure.
Liquid refrigerant flows through the metering valve into the evaporator. The restriction across the metering valve reduces the pressure and temperature of the refrigerant. The restriction also changes the liquid stream of refrigerant into a fine spray, to improve the evaporation process. As the refrigerant passes through the evaporator, it absorbs heat from the air flowing through the evaporator. The increase in temperature causes the refrigerant to vaporize and increase in pressure.
The temperature and pressure of the refrigerant leaving the evaporator acts on the diaphragm and temperature sensitive tube, which regulate the metering valve opening and so control the volume of refrigerant flowing through the evaporator. The warmer the air flowing through the evaporator, the more heat available to evaporate refrigerant and thus the greater volume of refrigerant allowed through the metering valve.

EVAPORATOR





The evaporator is installed in the heater assembly, between the blower and the heater core, to absorb heat from the exterior or recirculated air. Low pressure, low temperature refrigerant changes from liquid to vapor in the evaporator, absorbing large quantities of heat as it changes state.
Most of the moisture in the air passing through the evaporator condenses into water, which drains out of the vehicle by passing through a drain tube to the underside of the vehicle.

REFRIGERANT LINES
To maintain similar flow velocities around the A/C system the diameter of the refrigerant lines varies to suit the 2 pressure/temperature regimes. Larger diameter pipes are installed in the low pressure/temperature regime and smaller diameter pipes are installed in the high pressure/temperature regime.
Nylon lined, low permeability rubber hoses are used in the low pressure line into the A/C compressor, and in the high pressure line from the condenser. The remainder of the refrigerant lines are manufactured from steel.
Low and high pressure charging connections are incorporated into the refrigerant lines for system servicing.

CONTROL DIAGRAM

NOTE:
A = Refrigerant liquid; B = Refrigerant vapor; C = Air flow









PRINCIPLES OF OPERATION
To accomplish the transfer of heat, the refrigerant is circulated around the system, where it passes through 2 pressure/temperature regimes. In each of the regimes the refrigerant changes state, during which process maximum heat absorption or dissipation occurs.
The low pressure/temperature regime is from the thermostatic expansion valve, through the evaporator to the compressor. The refrigerant decreases in pressure and temperature at the thermostatic expansion valve then changes state from a liquid to a vapor in the evaporator to absorb heat.
The high pressure/temperature regime is from the compressor, through the condenser and receiver drier assembly to the thermostatic expansion valve. The refrigerant increases in pressure and temperature as it passes through the compressor, then releases heat and changes state from a vapor to a liquid in the condenser.
Operation of the A/C system is controlled by the Automatic Temperature Control (ATC) module. For additional information, refer to Control Components Control Components