Operation CHARM: Car repair manuals for everyone.

Cooling Module






Cooling Module
This is a "Trustmark Authoring Standards (TAS) Repair Procedure"
- TAS style procedures can be identified by steps that have no accompanying step text and the magenta color of the electrical connectors and fasteners such as nuts, bolts, clamps or clips.
- TAS removal and installation procedures use a sequence of color illustrations to indicate the order to be followed when removing/disassembling or installing/assembling a component.
- Many of the TAS procedures will have the installation information within the removal steps.
- The TAS color illustrations use a variety of symbols to indicate important details of the procedures. It is important to understand these symbols in order to properly used the TAS procedures.
Refer to How to Use TAS Procedures and TAS Symbol Glossary at Vehicle | Description and Operation for additional information on these TAS procedures.
For additional information, refer to How to Use TAS Procedures How to Use TAS Procedures

Removal

NOTE:
Removal steps in this procedure may contain installation details.
For additional information, refer to Battery Disconnect and Connect
For additional information, refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging

WARNING: Make sure to support the vehicle with axle stands.
1 Raise and support the vehicle.





NOTE:
Some variation in the illustrations may occur, but the essential information is always correct.

WARNING: Since injury such as scalding could be caused by escaping steam or coolant, do not remove the filler cap from the coolant expansion tank while the system is hot.

WARNING: Be prepared to catch escaping fluid.
For additional information, refer to Cooling System Draining, Filling and Bleeding - Vehicles Without: Supercharger









CAUTION: A new O-ring seal is to be installed.

Torque to: 8 Nm





CAUTION: A new O-ring seal is to be installed.

Torque to: 8 Nm
2 Lower the vehicle.
For additional information, refer to Air Cleaner Outlet Pipe LH
For additional information, refer to Air Cleaner Outlet Pipe RH
For additional information, refer to Air Cleaner Outlet Pipe T-Connector
For additional information, refer to Air Cleaner RH
For additional information, refer to Air Cleaner LH





Torque to: 9 Nm





CAUTION: Be prepared to collect escaping coolant.













CAUTION: Be prepared to collect escaping coolant.

Installation
1 To install, reverse the removal procedure.