Operation CHARM: Car repair manuals for everyone.

Power Window

P15 POWER WINDOW MASTER SW
1-GROUND : Always approx. 12 Volts
3-GROUND : Approx. 12 Volts with ignition SW at ON or ST position
: Approx. 12 Volts with key off power window operation
9-GROUND : Always continuity
20-GROUND : Continuity with power window master SW at MANUAL UP position
: Continuity with power window master SW at AUTO UP position
8-GROUND : Continuity with power window master SW at MANUAL DOWN position
: Continuity with power window master SW at AUTO DOWN position

P12 POWER WINDOW CONTROL SW FRONT RH
7-GROUND : Always approx. 12 Volts
9, 12-GROUND : Always continuity
1-GROUND : Continuity with power window control SW at MANUAL UP position
: Continuity with power window control SW at AUTO UP position
6-GROUND : Continuity with power window control SW at MANUAL DOWN position
: Continuity with power window control SW at AUTO DOWN position

P13 POWER WINDOW CONTROL SW REAR LH
7-GROUND : Always approx. 12 Volts
10,12-GROUND : Always continuity
1-GROUND : Continuity with power window control SW at MANUAL UP position
: Continuity with power window control SW at AUTO UP position
6-GROUND : Continuity with power window control SW at MANUAL DOWN position
: Continuity with power window control SW at AUTO DOWN position

P14 POWER WINDOW CONTROL SW REAR RH
7-GROUND : Always approx. 12 Volts
12-GROUND : Always continuity
1-GROUND : Continuity with power window control SW at MANUAL UP position
: Continuity with power window control SW at AUTO UP position
6-GROUND : Continuity with power window control SW at MANUAL DOWN position
: Continuity with power window control SW at AUTO DOWN position