Oxygen Sensor: Testing and Inspection
INSPECTION
1. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSORS
(a) Disconnect the oxygen sensor connector.
(b) Using an ohmmeter, measure the resistance between terminals +B and HT.
Resistance: 11 - 16 ohms at 20°C (68°F)
If the resistance is not as specified, replace the sensor.
Torque: 44 N.m (450 kgf.cm, 32 ft.lbf) for sensor 1
20 N.m (200 kgf.cm, 14 ft.lbf) for sensor 2
(c) Reconnect the oxygen sensor connector.
2. INSPECT OPERATION OF HEATED OXYGEN SENSORS