Wireless Door Lock Control System
TERMINALS OF ECU1. INSTRUMENT PANEL JUNCTION BLOCK (MULTIPLEX NETWORK BODY ECU)
a. Disconnect the instrument panel J/B and multiplex network body ECU connectors.
b. Check the voltage or resistance according to the value(s) in the table(wire harness side connector).
HINT: If the result is not as specified, there may be a malfunction on the wire harness side.
c. Reconnect the instrument panel J/B and multiplex network body ECU connectors.
d. Check the voltage according to the value(s) in the table (ECU side connector).
If the result is not as specified, the instrument panel J/B (multiplex network body ECU) may have a malfunction.