Operation CHARM: Car repair manuals for everyone.

Removal and Installation

COMBINATION METER

REMOVAL

1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION: Wait for 90 seconds after disconnecting the cable to prevent the airbag working.

2. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY




a. Disengage the 4 clips and remove the instrument cluster finish panel sub-assembly.

3. REMOVE COMBINATION METER ASSEMBLY




a. Remove the 4 screws.
b. Pull out the combination meter assembly, and disconnect the connectors.

INSTALLATION

1. INSTALL COMBINATION METER ASSEMBLY
a. Connect the connectors.




b. Install the combination meter assembly with the 4 screws.

2. INSTALL INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY




a. Engage the 4 clips and install the instrument cluster finish panel sub-assembly.

3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
4. PERFORM INITIALIZATION

NOTE: Some systems need initialization when disconnecting the cable from the negative battery terminal.