Height Control Sensor (for Front Side)
SUSPENSION CONTROL: HEIGHT CONTROL SENSOR (for Front Side): INSPECTION
1. INSPECT FRONT HEIGHT CONTROL SENSOR SUB-ASSEMBLY
(a) Connect 3 dry batteries of 1.5 V in series.
(b) Connect a positive (+) lead from the batteries to terminal 3 (SHB) of the height control sensor and a negative (-) lead to terminal 1 (SHG). While applying 4.5 V, slowly moving the sensor link up and down, and measure the voltage between terminal 2 (SHFR*1 or SHFL*2) and terminal 1 (SHG).
HINT
* *1: for RH
* *2: for LH
Standard Voltage:
for RH
for LH
NOTICE:
* Do not apply more than 6 V.
* Do not drop the height control sensor. If it is dropped, replace it with a new one.
(c) If the value is not as specified replace the front height control sensor sub-assembly.