Odo/Trip Switch Malfunction
METER / GAUGE / DISPLAY: METER / GAUGE SYSTEM: Odo/Trip Switch Malfunction
- Odo/Trip Switch Malfunction
DESCRIPTION
The meter CPU receives ODO/TRIP change switch signal from the light control rheostat via the direct line.
HINT
The whole light control switch should be replaced if the ODO/TRIP switch is malfunctioning.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. READ VALUE USING TECHSTREAM (ODO/TRIP CHANGE SW)
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Combination Meter / Data List.
(e) Check the values by referring to the table below.
Combination Meter
OK:
The value displayed on the Techstream changes with the actual ODO/TRIP change switch operation.
NG -- INSPECT LIGHT CONTROL RHEOSTAT
OK -- REPLACE COMBINATION METER ASSEMBLY Removal
2. INSPECT LIGHT CONTROL RHEOSTAT
(a) Remove the light control rheostat Removal.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPLACE LIGHT CONTROL RHEOSTAT Removal
OK -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT)
(a) Disconnect the F16 connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE COMBINATION METER ASSEMBLY Removal