Ignition System: Adjustments
Inspecting Distributor Air Gap:
Note: Air gap is not adjustable, this procedure is for inspection only.
- Using a 0.008 - 0.016 in (0.2 - 0.4 mm) feeler gauge inspect air gaps for both sensors.
- If any air gap is not as specified, replace distributor.