Operation CHARM: Car repair manuals for everyone.

Interior Floor Board - Vibration at 1700 RPM


90lexus05 NVH 001 12-21-90 LS400

Title PIPE SUPPORT BRACKET




To reduce floor vibration at 1700 RPM, the No. 1 and No. 2 exhaust pipe support brackets have been combined into one unit as shown in the illustration below.

PRODUCTION EFFECTIVE:

Starting VIN Production Date
JT8UF11E-M0045413 August 1990

PART NUMBER INFORMATION:


PREVIOUS P/N NEW P/N PART NAME QTY/VEH

17571-50020 N/A Bracket, Exh Pipe Support No.1 1

17572-50010 N/A " " " " No.2 1

N/A 17506-50030 Bracket Sub-Assy, Exh Pipe 1
Support

91652-61020 190119-10668 Bolt, w/ Washer 4

Parts are interchangeable as a set only.




REPAIR PROCEDURE:

1. Remove and discard original Exhaust Pipe Support Brackets No. 1 and No. 2.

2. Install the modified Exhaust Pipe Support Bracket Sub-assembly.

a. Hand-tighten the four new bolts which attach the bracket to the transmission through rubber bushings.

b. Align the bracket to the catalytic converters and install the two bolts.
c. Torque the four bolts with rubber bushings (bracket-totransmission) to 32 ft.lbs. (400 kg. cm., 43 N-m).

NOTE: All bolt holes should be in alignment. If they are not, the bracket may be placed in a bind, and the vibration may not be eliminated.