Service Hints
P 8 POWER WINDOW MASTER SW AND DOOR LOCK CONTROL SW8-GROUND: APPROX. 12 VOLTS WITH IGNITION SW AT ON POSITION
4-GROUND: ALWAYS CONTINUITY
3-GROUND: APPROX. 12 VOLTS WITH IGNITION SW ON AND MASTER SW (DRIVER'S WINDOW) UP
6-GROUND: APPROX. 12 VOLTS WITH IGNITION SW ON AND MASTER SW (DRIVER'S WINDOW) AT DOWN OR AUTO DOWN POSITION
WINDOW LOCK SW
OPEN WITH WINDOW LOCK SW AT LOCK POSITION