Operation CHARM: Car repair manuals for everyone.

Control Panel Inspection Procedure:

CONTROL PANEL INSPECTION PROCEDURE





Interior Circuits

INSPECTION PROCEDURE:





1. Bulb Circuit -

Perform the following tests on suspect Night Illumination Bulbs. Check for continuity as shown. Replace the bulb if there is no continuity.





2. Bulb Circuit Inspection

Verify continuity between terminals 24 - 26, if no continuity replace the Control Switch.








3. Switch Circuit -

a. Switch Continuity Inspection:

- Check that there is continuity between the terminals while the switch is pressed.

- If there is no continuity between even one pair of terminals, replace the Control Switch.

* Added beginning August 1993.











b. Dial Switch Continuity inspection -

- Check terminal continuity between 32 and 27 - 31.

- Rotate the Dial Switch to positions 1 through 23 and check for continuity/no continuity.

- If continuity is not as identified on the chart, Control Panel replacement is required.

- Chart Legend -

CONTINUITY:
1 - Yes
0 - No





4. Indicator Lamp Circuit -

Connect two 1.5 v dry cell batteries in series. Using the table, check that each suspect Indicator Lamp illuminates.

NOTE:
Since the Indicator Lamps are LEDs, do not mix the "+" and "-" terminals of the test batteries or apply power to them for more than 3 seconds at a time.

If a suspect LED does not illuminate when tested, replace the Control Switch.