Exhaust Gas Recirculation: Testing and Inspection
Modulator Filter Cleaning:
Preparation
- Remove vacuum modulator.
- Remove modulator cap and filter.
- Clean modulator filter with compressed air.
Connecting Tachometer:
VSV Operation
- Engine temperature should be below 113°F (45°C).
- Connect tachometer to IG terminal of the data link connector.
Installing Jumper Wire:
- Install jumper wire between terminals TE1 and E1 of the data link connector.
- Start engine and run at 3,500 rpm in Neutral.
- Remove jumper wire while observing tachometer.
Desired - No rpm increase
- Warm engine to above 122°F (50°C) and repeat test.
Desired - Engine speed increases 100 to 300 rpm.