Continuity Check (Open Circuit Check)
1. CONTINUITY CHECK (OPEN CIRCUIT CHECK)
- Disconnect the connectors at both ECU and sensor sides.
- Measure the resistance between the applicable terminals of the connectors.
Resistance: 1 Ohms or less
HINT:
- Measure the resistance while lightly shaking the wire harness vertically and horizontally.
- When tester probes are inserted into a connector, insert the probes from the back.
- For waterproof connectors in which the probes cannot be inserted from the back, be careful not to bend the terminals when inserting the tester probes.