Pull-In Test
Fig. 3 Pull-in Test Connection Locations:
Fig. 4 Pull-in Test Connection Locations:
1. Disconnect field coil wire from terminal C.
2. Connect battery (+) to terminal 50 of starter, battery (-) to terminal C and starter body, Figs. 3 and 4. Pinion gear should move outward. If not, replace magnetic switch assembly.