Power Seat Motor: Testing and Inspection
INSPECT SLIDE MOTOR OPERATION
a. Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1, check that the motor turns counterclockwise.
b. Reverse the polarity, check that the motor turns clockwise.
If operation is not as specified, replace the motor.
INSPECT SLIDE MOTOR PTC THERMISTOR OPERATION
Driver's seat:
a. Connect the positive (+) lead from the battery to terminal 2, the positive (+) lead from the ammeter to terminal 1, and the negative (-) lead to battery negative (-) terminal, and move the seat front end position.
b. Continue to apply voltage, check the current changes to less than 1 ampere within 4 to 90 seconds.
c. Disconnect the lead from terminals.
d. Approximately 60 seconds later, connect the positive (+) lead from battery to terminal 1 and the negative (-) lead to terminal 2, check that the seat begins to move backwards.
If operation is not as specified, replace the motor.
INSPECT FRONT VERTICAL MOTOR OPERATION
a. Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1, check that the motor turns clockwise.
b. Reverse the polarity, check that the motor turns counter clockwise.
If operation is not as specified, replace the motor.
INSPECT FRONT VERTICAL MOTOR PTC THERMISTOR OPERATION
Driver's Seat:
a. Connect the positive (+) lead from the battery to terminal 1, the positive (+) lead from the ammeter to terminal 2 and the negative (-) lead to battery negative (-) terminal, and move the front edge of seat cushion to the highest position.
b. Continue to apply voltage, check the current changes to less than 1 ampere within 4 to 90 seconds.
c. Disconnect the leads from terminals.
d. Approximately 60 seconds later, connect the positive (+) lead from battery to terminal 2 and the negative (-) lead to terminal 1, check that the seat cushion begins to descend.
If operation is not as specified, replace the motor.
INSPECT REAR VERTICAL MOTOR OPERATION
a. Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1, check that the motor turns clockwise.
b. Reverse the polarity, check that the motor turns counterclockwise.
If operation is not as specified, replace the motor.
INSPECT REAR VERTICAL MOTOR PTC THERMISTOR OPERATION
Driver's seat:
a. Connect the positive (+) lead from the battery to terminal 2, the positive (+) lead from the ammeter to terminal 1 and the negative (-) lead to battery negative (-) terminal, and move the rear edge of seat cushion to the highest position.
b. Continue to apply voltage, check the current changes to less than 1 ampere within 4 to 90 seconds.
c. Disconnect the leads from terminals.
d. Approximately 60 seconds later, connect the positive (+) lead from battery to terminal 1 and the negative (-) lead to terminal 2, check that the seat cushion begins to descend.
If operation is not as specified, replace the motor.
INSPECT RECLINING MOTOR OPERATION
Driver's Seat:
a. Connect the positive (+) lead from the battery to terminal 2 and negative (-) lead to terminal 1 and check that the motor turns counterclockwise.
b. Reverse the polarity, check that the motor turns clockwise.
If operation is not as specified, replace the motor.
INSPECT RECLINING MOTOR PTC THERMISTOR OPERATION
Driver's Seat:
a. Connect the positive (+) lead from the battery to terminal 1, the positive (+) lead from the ammeter to terminal 2 and the negative (-) lead to battery negative (-) terminal, and recline the seat back to the most forward position.
b. Continue to apply voltage , check the current change to less than 1 ampere within 4 to 90 seconds.
c. Disconnect the lead from terminals.
d. Approximately 60 seconds later, connect the positive (+) lead from battery to terminal 2 and the negative (-) lead to terminal 1, check that the seat back starts to fall backwards.
If operation is not as specified, replace the motor.
INSPECT LUMBAR SUPPORT MOTOR OPERATION
a. Connect the positive (+) lead from the battery to terminal 1 and the negative (-) lead to terminal 2, check that the lumbar support moves backward.
b. Reverse the polarity, check that the lumbar support moves forward.
If operation is not as specified, replace the motor.
INSPECT LUMBAR SUPPORT MOTOR CIRCUIT BREAKER OPERATION
a. Connect the positive (+) lead from the battery to terminal and the negative (-) lead to terminal on the lumbar support motor connector and move the lumbar support to front end position.
b. Continue to apply voltage, check that there is a circuit breaker operation noise within 4 to 60 seconds.
c. Reverse the polarity check that the lumbar support begins to move release side within approximately 60 seconds.
If operation is not as specified, replace the motor.