Extension Housing
EXTENSION HOUSINGEXTENSION HOUSING INSPECTION
INSPECT EXTENSION HOUSING BUSHING
Using a cylinder gauge, measure the inside diameter of the extension housing bushing.
Maximum inside diameter: 40.09 mm (1.5783 inch)
If the inside diameter is greater than the maximum, replace the extension housing.