Service Hints
INTEGRATION RELAY [INSTRUMENT PANEL J/B]1-GROUND : Always approx. 12 volts
4-GROUND : Continuity with each door (Front RH, rear LH and RH) open
6-GROUND : Continuity with the driver's door open
D 9, D 10, D 11, D 12 DOOR COURTESY SW FRONT LH, RH, REAR LH, RH
1-GROUND : Closed with each of the doors open