Component Tests and General Diagnostics
INSPECTION1. INSPECT STOP LIGHT SWITCH CONTINUITY
If continuity is not as specified, replace the switch.
2. INSPECT STOP LIGHT SWITCH CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side.
If circuit is not as specified, inspect the power source or wire harness.
3. INSPECT HIGH-MOUNTED STOP LIGHT ASSEMBLY CONTINUITY
Using the ohmmeter, check that continuity exists between terminals.
If continuity is not as specified, replace the bulb or light assembly.
4. INSPECT HIGH-MOUNTED STOP LIGHT ASSEMBLY CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side.
If circuit is not as specified, inspect the power source or wire harness.
5. INSPECT LIGHT FAILURE SENSOR CIRCUIT
Disconnect the connector from the sensor and inspect the connector on the wire harness side.
If the circuit is as specified, replace the sensor.
If the circuit is not as specified, inspect the circuits connected to other parts.