Operation CHARM: Car repair manuals for everyone.

Hose/Line HVAC: Service and Repair

Refrigerant Line:






REPLACEMENT

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
2. REPLACE FAULTY TUBE OR HOSE

NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.




3. TIGHTEN JOINT OF BOLT OR NUT TO SPECIFIED TORQUE

NOTE: Connections should not be torqued tighter than the specified torqued.

4. EVACUATE AIR FROM REFRIGERATION SYSTEM AND CHARGE SYSTEM WITH REFRIGERANT

Specified amount: 600 ± 50 g (21.16 ± 1.76 oz.)

5. INSPECT FOR LEAKAGE OF REFRIGERANT
Using a gas leak detector, check for leakage of refrigerant.

6. INSPECT AIR CONDITIONING OPERATION