Operation CHARM: Car repair manuals for everyone.

Oxygen Sensor

HEATED OXYGEN SENSORS (BANK 1, 2 SENSOR 1 AND BANK 1 SENSOR 2)
Using an ohmmeter, measure the resistance between the terminals +B and HT.

Resistance: 11 - 16 ohms at 20 °C (68 °F)


HEATED OXYGEN SENSOR (BANK 2 SENSOR 2)
Using an ohmmeter, measure the resistance between the terminals +B and HT.

Resistance: 11 - 16 ohms at 20 °C (68 °F)