Operation CHARM: Car repair manuals for everyone.

Service Hints

G1 (A), G2 (B) GENERATOR
(A) 1 - GROUND : 13.8 - 15.0 volts with the engine running at 5000 rpm and 25 °C (77 °F)
: 13.2 - 14.0 volts with the engine running at 5000 rpm and 115 °C (239 °F)
(B) 1 - GROUND : Below 1.5 volts with the ignition SW at ON position and engine not running