Operation CHARM: Car repair manuals for everyone.

Power Source Circuit

ECU POWER SOURCE CIRCUIT

CIRCUIT DESCRIPTION

The position control ECU is contained in the switch assy.

When a switch is activated during manual operation, all other signals are ignored, i.e. if more than one ON signal from the switches are input at the same time, all of them are ignored. However, if the front vertical switch signal and the lifter switch are activated simultaneously, only the lifter switch can be activated. During automatic operation, a manual switch input overrides any other operations, i.e. automatic operations stop and the manual input operation are accepted. For example, if during a seat store/restore operation, a manual switch input is activated, the previous operation will cease and manual operation will be performed. After the manual operation is performed, the previous automatic operation will not resume. Adjustable pedal and power mirror store/restore operation is unaffected by manual switch inputs.

The position control ECU & switch assy disallows the restore operation of the power seat when the system detects that the voltage of terminal SYSB is less than 8 V for 0.3 seconds or is more than 10 V for 30 seconds. The given circuit is a power source circuit of the position control ECU & switch assy.

HINT: Manual adjustment of the slide reclining lumbar can be performed even when the ECU is not functional if current is allowed to flow into terminals +B and SYSB.
Lumbar operation can always be performed.

Wiring Diagram:






Step 1 - 2:




INSPECTION PROCEDURE