P0877
DTC P0877 Transmission Fluid Pressure Switch No. 2 Circuit LowDTC P0878 Transmission Fluid Pressure Switch No. 2 Circuit High
DESCRIPTION
ATF pressure switch No. 2 is installed in the shift solenoid valve ATF output passage. This switch is used to identify the malfunctioning part when a fail-safe operation is performed. If the shift solenoid valve malfunctions when the ATF pressure switch has a malfunction, a fail-safe operation will be performed. This fail-safe operation is different from the fail-safe operation performed when the solenoid valve malfunctions and the ATF pressure switch is normal.
WIRING DIAGRAM:
INSPECTION PROCEDURE