Short to GND in CAN Bus Line
Short to GND in CAN Bus LineDESCRIPTION
A short to GND is suspected in the CAN bus wire when the resistance between terminals 4 (CG) and 6 (CANH), or terminals 4 (CG) and 14 (CANL) of the DLC3 is below 200 Ohm.
Wiring Diagram (Part 1):
Wiring Diagram (Part 2):
Step 1:
Step 2-3:
Step 3 (Continued):
Step 3 (Continued):
Step 3 (Continued)-4:
Step 4 (Continued)-5:
Step 5 (Continued)-6:
Step 6 (Continued)-7:
Step 7 (Continued)-8:
INSPECTION PROCEDURE
NOTE: Before measuring the resistance, leave the vehicle as is for at least 1 minute and do not operate the engine switch, any other switches, or the doors. If any doors need to be opened in order to check connectors, open the doors and leave them open.