Instrument Cluster / Carrier: Service and Repair
Combination Meter:
COMBINATION METER
REMOVAL
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
2. REMOVE STEERING COLUMN COVER UPPER
3. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY
a. Using a screwdriver, detach the 5 clips.
HINT: Tape the screwdriver tip before use.
b. Remove the cluster finish panel and then disconnect the connector.
4. REMOVE COMBINATION METER ASSEMBLY
a. Remove the 4 screws.
b. Disconnect the connector and remove the combination meter.
5. REMOVE COMBINATION METER GLASS
a. Using a screwdriver, detach the 2 claws and open the cover.
HINT: Tape the screwdriver tip before use.
b. Disconnect the 3 connectors.
c. Detach the 7 claws and remove the glass.
INSTALLATION
1. INSTALL COMBINATION METER GLASS
a. Install the glass and attach the 7 claws.
b. Install the combination meter glass's wire harness with the clamps.
c. Connect the 3 connectors.
d. Close the cover.
e. Attach the 2 claws.
2. INSTALL COMBINATION METER ASSEMBLY
a. Connect the connector.
b. Install the combination meter with the 4 screws.
3. INSTALL INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY
a. Connect the connector.
b. Attach the 5 clips to install the cluster finish panel.
4. INSTALL STEERING COLUMN COVER UPPER
5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
6. PERFORM INITIALIZATION
NOTE: Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal. Perform initialization.
7. CHECK SRS WARNING LIGHT
Check SRS warning light.Refer to Restraint Systems Service Precautions.