Operation CHARM: Car repair manuals for everyone.

P3232

DTC P3232-749 Open or Short to B+ in Blocking of HV Gate Connection

DESCRIPTION

DTC Detection Condition:




The hybrid vehicle control ECU sends a shutdown signal to the inverter with converter assembly (MG ECU) to shut down the power supply to MG2.

Wiring Diagram:






Step 1(Continued)-2:




INSPECTION PROCEDURE

CAUTION:
- Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting, check the voltage at the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.


HINT:
- Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
- When attempting to reproduce the problem, turning the power switch on (IG) and off repeatedly makes it easier to reproduce the problem. Do not repeat the operations of turning the power switch on (READY) and turning the power switch off as these will activate system main relay overheat protection.