Scan Tool Testing and Procedures
ENGINE HOOD / DOOR: POWER TRUNK LID SYSTEM: DATA LIST / ACTIVE TEST
DATA LIST / ACTIVE TEST
1. DATA LIST
HINT: Using the intelligent tester or Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
(a) Connect the intelligent tester or Techstream to the DLC3.
(b) Turn the power switch ON (IG).
(c) Turn the tester on.
(d) Enter the following menus:
(1) Intelligent tester - Select: DIAGNOSIS / OBD/MOBD / (desired system) / DATA LIST / ALL.
(2) Techstream - Select: Body Electrical / (desired system) / Data List.
(e) According to the display on tester, read the "Data List".
(1) Intelligent tester
MAIN BODY:
BODY NO. 4:
HINT: Even though LUGG PUSH SW and luggage compartment door closer assembly switch items are displayed in the BODY NO. 4 Data List, use the PBD/PTL Data List to determine whether a part is faulty or not.
BACK-DOOR:
(2) Techstream
Main Body:
Body No. 4:
HINT: Even though Luggage Push Switch and luggage compartment door closer assembly switch items are displayed in the Body No. 4 Data List, use the Back Door Data List to determine whether a part is faulty or not.
Back Door:
2. ACTIVE TEST
HINT: Using the intelligent tester or Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
(a) Connect the intelligent tester or Techstream to the DLC3.
(b) Turn the power switch ON (IG).
(c) Turn the tester on.
(d) Enter the following menus:
(1) Intelligent tester - Select: DIAGNOSIS / OBD/MOBD / (desired system) / ACTIVE TEST.
(2) Techstream - Select: Body Electrical / (desired system) /Active Test.
(e) According to the display on tester, perform the "Active Test".
(1) Intelligent tester
BACK-DOOR:
HINT: Even though TRUNK LID OPEN is displayed in the BODY NO. 4 Active Test, use the PBD/PTL Active Test to check the operation.
(2) Techstream
Back Door: